The LX-980 time -frequency synchronization analyzer adopts the flat-panel operation mode, and is com...
Description
The LX-980 time -frequency synchronization analyzer adopts the flat-panel operation mode, and is compatible with GPS/BD signal access, as well as high -quality tame rubidium atomic clock. It has the characteristics of powerful function, high accuracy, and long endurance. It can accurately measure the pulse signal, IRIG - B AC and DC, serial port time message, SNTP network time message, and IEEE1588 precise network time synchronization message and other time synchronization signals, and can automatically identify the type of measured signal, It supports the measurement of the accuracy, standard deviation, amplitude, pulse width, etc. of the time signal, and can reproduce high -precision UTC time and generate high -precision clock as the test benchmark. It is applicable to power supply bureaus, power transmission and transformation companies, maintenance companies, electric power research institutes, enterprises and institutions that need time calibration, time measurement and time testing.
It supports the storage of PTP timestamp original data (T1, T2, T3, T4) and correction domain, and can quickly perform fault location and abnormal cause analysis.
Main features
○Dual power supply redundancy hardware design
○Message processing based on hardware timestamp
○User configurable PTP/NTP
○Telecom in accordance with ITU-T G.8265 . 1 standard
○Support 2-channel satellite time source input
○Automatic switching to select preferred reference source
○WEB/SNMP management
Product technical indicators
GNSS Input Options Test signal type
Measurement content
Parse content | ○ GPS 、GLONASS 、GALILEO 、BeiDou ○ 1PPS/PPM/PPH (TTL / RS485 / RS422 / RS232 /) ○ IRIG-B (DC) (TTL / RS485 / RS422 / RS232) ○ Serial port Time message (RS485 / RS422 / RS232 ) ○ PTP / NTP / SNTP Network Time message Level high and low amplitude, rising edge time, pulse signal width, time accuracy of second timing, standard deviation of time accuracy, SOE, etc., support single or continuous measurement. ○ IRIG-B, serial port time message, PTP/NTP/SNTP network time message ○ Completion of time deviation/drift test and PDV test ○ Store PTP timestamp original data (T1, T2, T3, T4) and correction domain for fault location and abnormal cause analysis ○ PTP, NTP, 1PPS+TOD and other message information are captured and analyzed for a long time (supporting 500G data storage) |
Self-maintenance
stability of the device ○ It is better than 50ns/h, and supports continuous and long time self-keeping accuracy measurement record
Resolution ○ Time and clock test resolution 100ps
Frequency stability
of automorphic time ○ 3 × E- 11/month, rubidium clock: better than (including) 1 μS/day; OCXO: better than (including) 1 μs/h;Taming time:≥ 12h
Accuracy of
measurement content ○ 1PS/PPM/PPH pulse signal is better than 50ns
○ IRIG-B (DC) is better than 50ns
○ IRIG-B (AC) is better than 50ns
○ Serial port message is better than 50ns
○ PTP network time message is better than 50ns
Copyright 2015-2020 Shenzhen Lixing Sifang Electronics Co., Ltd. All rights reserved Record number:粤ICP备2025428050号 support:易畅客营销系统